In the mid-1980s, the TIA (Telecommunications Industry Association) and the EIA (Electronic Industries Association) began developing methods for cabling buildings, with the intent of developing a uniform wiring system that would support multivendor products and environments.

In 1991, the TIA/EIA released the TIA/EIA 568 Commercial Building Telecommunication Cabling standard. Note that the ISO/IEC-11801 Generic Customer Premises Cabling standard is an international cabling standard that is based on the ANSI/TIA/EIA-568 cabling standard.

The TIA/EIA structured cabling standards define how to design, build, and manage a cabling system that is structured, meaning that the system is designed in blocks that have very specific performance characteristics. The blocks are integrated in a hierarchical manner to create a unified communication system.

TIA 568-B.1-2000 (Commercial Building Telecommunications Wiring Standard)    The year 2000 update packages all the previous addendums and service updates into a new release and, most important, specifies that Category 5E cable is the preferred cable type that can provide minimum acceptable performance levels. Several addendums were also released that specify technical information for 100-ohm twisted-pair cable, shielded twisted-pair cable, and optical fiber cable.

The TIA standard defines the parameters for each part of the cabling system, which includes work area wiring, horizontal wiring, telecommunication closets, equipment rooms and cross- connects, backbone (vertical) wiring, and entrance facilities.

Cable Systems is responsible for providing connectivity through devices such as:

  • Data transmission system (Data).

  • Network information system (Telephone).

Other applications of intelligent building: Camera IP, BMS,…

The benefits of structured cabling system

  • Cable systems can exist during the life of the building.

  • A wide variety of devices from different manufacturers may simultaneously exist.

  • Network resources are always ready with structured cabling system when the company looking for expansion or relocation opportunities.

  • With Cat6 cables or fiber optic cabling, can support future applications, without upgrading.

  • Changes, displacement and rearrange work area or upgrading can reduce the costs by 20 to 40 percent for replacement equipment and accessories.

  • Can reduce the costs 30 percent with integration between cable systems and how to deliver service. Utilities for system administrators.

1. The components for structured cabling system

Follow TIA/EIA, the main components of structured cabling system:

  • Work Area
  • Horizontal Cabling
  • Telecommunications Room
  • Backbone Cabling
  • Equipment Room
  • Entrance Facilities
  • Administration

1.1. Work Area

Connect end-user equipment to outlets of the horizontal cabling system

1.2. Horizontal Cabling

Wiring can be IW (inside wiring) or Plenum Cabling and connects telecommunications rooms to individual outlets or work areas on the floor, usually through the wireways, conduits or ceiling spaces of each floor..

1.3. Telecommunications Room

Or Telecommunications Enclosure connects between the backbone cabling and horizontal cabling.

1.4. Backone Cabling

Connects between the equipment/telecommunications rooms, so named because the rooms are typically on different floors.

1.5. Equipment Room

House equipment and wiring consolidation points that serve the users inside the building or campus.

1.6. Entrance Facility

Is the Point where the telephone company network ends and connects with the on-premises wiring at the customer premises.

1.7. Administration

Includes labeling, Create profile, drawings... allow administrator can manage all devices of the Whole System that can be easily upgraded if necessary.

2. Model structured cabling systems:

A structured cabling system is designed based on two main models which are Distribution Network Applications (DNA) and Centralized Network Administration (CNA).

2.1. Distribution Network Applications (DNA)

In this model, cable system on every floor is pulled into  cabinets on every floor, from  these cabinets will be connected to the Central Box through the Backbone.

This model has advantages and disadvantages:

  • Advantages
    • Using for large buildings and campus areas
    • Based on the TIA/EIA/ISO standards

    • Reducing the number of cables

  • Disadvantages
    • Needing more electronic devices (converter,switch,…)

    • Not convenient for MAC

    • Increasing time and cost management

    • Don't utilize efficiently network ports

2.2. Centralized Network Administration (CNA)

In this model, cable system  is pulled into the Central Box located central location of the Whole System.

This model has advantages and disadvantages::

  • Advantages
    • MAC simple, inexpensive

    • Reducing time and cost management

    • Utilizing efficiently network ports

    • Based on the TIA/EIA TSB-72 standards

    • Reducing space for Telecomunications closet

    • Easy Relocation Cable

    • Reducing switch point damage
  • Disadvantages
    • High initial installation costs

    • Electronic equipment are high cost for fiber optic cables.

3.  Telecommunications Standards

Standard structured cabling systems must be designed, deployed, based on a system of international standards, the most current standard is TIA/EIA:

3.1. TIA/EIA-568B

This Standard is a family of Telecommunications Standards that the Telecommunications Industry Association (TIA) TR-42 Technical Committee has broken the standard into a series of documents known as B.1, B.2 and B.3

Goals: defines structured cabling system standards for commercial buildings, and between buildings in campus environments. The bulk of the standards define cabling types, distances, connectors, cable system architectures, cable termination standards and performance characteristics, cable installation requirements and methods of testing installed cable.

3.2. TIA/EIA-569B

The Telecommunications Industry Association's TIA-569-B is a Commercial Building Standard for Telecommunications Pathways and Spaces standardizes specific pathway and space design and construction practices in support of telecommunications media and equipment within buildings.   

Goals: A principal goal of this Standard is to be useful to the building owners and occupants who otherwise would live with the daily problems associated with buildings that are not properly designed and constructed to support telecommunications. A properly designed and constructed facility is adaptable to change over the life of the facility. Owners and occupants should assume that better telecommunications facilities are constructed through the use of this Standard. Indeed, part of the expected usefulness of this Standard is that it be referenced in documents such as bid requests, specifications, and contracts leading up to the construction of the facilities.

3.3. TIA/EIA-606A

The primary objective of the administration standard is to provide a uniform administration scheme that is independent of applications. Applications are expected to change several times during the lifetime of the premises. The Revised Version was created considering the need for a user-friendly applicable method.   

Goals: This Standard provides guidelines and choices of classes of administration for maintaining telecommunications infrastructure. Four classes of administration are specified. These classes are based on the complexity of the infrastructure being administered and are allowing a modular and scalable implementation.

3.4. ANSI-J-STD-607A

This standard is Commercial Building Grounding (Earthing) and Bonding Requirements For Telecommunications

Goals: To enable the planning, design, and installation of telecommunications grounding and bonding systems within a building with or without prior knowledge of the telecommunications systems that will subsequently be installed. This Standard also provides recommendations for grounding and bonding of customer owned towers and antennas. This telecommunications grounding and bonding infrastructure supports a multivendor, multiproduct environment as well as various system installation practices.

3.5. TIA/EIA-942

This standard is an American National Standard (ANS) that specifies the minimum requirements for telecommunications infrastructure of data centers and computer rooms including single tenant enterprise data centers and multi-tenant Internet hosting data centers. The topology proposed in the standard was intended to be applicable to any size data center.

Goals: provides the mandatory provision of specialized facilities and organization of work areas. In particular, this space for liner external telecommunication systems (Entrance Room), computer hardware (Computer Room), telecommunications equipment (Telecommunications Room) and accommodation for engineering systems, eg, electrical, industrial space conditioning and ventilation systems, etc.

3.6. TIA/EIA-862

Building Automation Systems

Cabling Standard for Commercial Buildings

Allowing the automatic control of all Security Systems, CCTV observation system, fire alarm system, Environmental Management System that controls temperature, humidity, Light management systems inside and outside the building...   

Goals: The standard specifies a generic cabling system for a building automation systems (BAS) used in commercials buildings. The purpose of this standard is to help in the planning and installation of a structured cabling system for BAS applications.